SP PRO SERIES SPECIFICATIONS |
SPMC240–AU |
SPMC241–AU |
SPMC481–AU |
SPMC482–AU |
SPLC1201–AU |
Nominal battery voltage |
24 V |
24 V |
48 V |
48 V |
120 V |
Continuous output power
at 25°C |
3000 W |
4500 W |
5000 W |
7500 W |
18,000 W |
Continuous charge current
at 25°C |
105 A |
146 A |
83 A |
125 A |
125 A |
20 second load rating
at 40°C |
7500 W |
10500 W |
12000 W |
18000 W |
30,000 W |
20 second output current
at 40°C |
28 A |
40 A |
47 A |
70 A |
110 A |
1 minute output power
at
40°C |
5400 W |
7600 W |
8700 W |
13000 W |
20,000 W |
60 minute output power
at
40°C |
3200 W |
4700 W |
5300 W |
8000 W |
20,000 W |
DC input voltage range |
20 - 34 V |
20 - 34 V |
40 - 68 V |
40 - 68 V |
100 - 170 V |
TRANSFER SWITCH |
AC transfer current capacity |
63 A |
125 A |
Max AC input source, (generator) W |
15 kVA |
30 kVA |
Max total output to Load, AC source + inverter |
15 kVA |
30 kVA |
AC transfer time |
no-break |
If grid fails |
0 - 0.03 seconds |
Battery charger type |
5 stage, power factor corrected with dual stage float |
DC consumption idle |
6 W |
Standby (adjustable rate) |
12 - 20 W |
n/a |
Models |
SPMC240–AU |
SPMC241–AU |
SPMC481–AU |
SPMC482–AU |
SPLC1201–AU |
ON with no load |
31 W |
36 W |
37 W |
40 W |
75 W |
Peak efficiency – all modes |
95% |
95% |
95.5% |
96% |
96% |
10% load |
90% |
90.5% |
91% |
91% |
91% |
20% load |
92.5% |
93% |
94% |
94% |
94% |
50% load |
94% |
94.5% |
95% |
95.5% |
95.5% |
100% load |
90% |
91% |
92.5% |
93% |
93% |
Max Grid Feed capacity |
rated output |
AC OUTPUT standalone |
Setting accuracy |
210 to 240 V+/- 0.5% |
Regulation |
<1% droop 0-100% rated load
(<2% at 150%, <5% at 200%, <10% at 300%) |
THD |
<3% at 0-200% rated load |
Frequency |
50 or 60 Hz +/-0.005% standalone |
AC SOURCE (input) |
Nominal voltage |
210 to 240 V~ |
Tolerance on nominal voltage |
programmable - 1% to 15%, + 1% to 10% |
Nominal input frequency |
50/60Hz |
Tolerance on nominal frequency |
programmable +/- 1% to 10% |
Generator can be started by |
battery SoC, DC voltage, battery load, unit temperature, time & remote control |
Battery temperature sensor |
Yes |
Mid point battery voltage sensing |
Yes |
Inverter display |
22 x LEDs with auto adjusting intensity.
Display indicates: charger status, remaining useable battery capacity, alarms, AC status.
AC status LEDs powered from AC voltage.
Generator control button.
Output mode button.
Alarm silence button. |
Digital Inputs |
4 x Max 60 VDC ( Active > +6V, Inactive < +3V ) |
Shunt Inputs |
2 x user definable: +/-75mV |
Analogue Inputs |
2 x general purpose logged 0-60V |
n/a |
Relay Outputs |
4 x 60 V, 500 mA |
Digital outputs |
3 x 60 V, 5 mA |
Communication ports |
2 x RS232 with adjustable baud rate of up to 57600 |
Memory retention of settings & data |
Permanent |
SP LINK configuration and monitoring software |
Standard.
Allows remote configuration of parameters
and viewing of LED & digital displays |
Dimensions (mounted) |
345 W x 545 H x 215 D |
520 W x 870 H
x 300 D |
Models |
SPMC240–AU |
SPMC241–AU |
SPMC481–AU |
SPMC482–AU |
SPLC1201-AU |
Weight |
29 kg |
34 kg |
35 kg |
40 kg |
105 kg |
Circuit Breakers
(AC Source, AC Load) |
Double pole 63A |
Single pole 125 A |
Standards |
AS/NZ61000-6-3 2007
AS62040.1.1-2003
AS4777 2005 (grid connect) |
AS/NZS 61000-6-4 2007
AS 4777 2005 pending |
Protection |
IP43 |
Warranty |
5 - 7 years, country dependent. (conditions apply) |
Availability |
Available now |
AS4777 Approval |
Approved and available on the Clean Energy Council list of Approved Grid Connect Inverters |
Through a policy of continual improvement, specifications may differ from those shown.